Guidebook on passive fire protection of steel structures (Record no. 45560)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 05358 a2200169 4500 |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 693.7 |
Item number | SAH |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Saha, Jayanta K. Com. |
245 ## - TITLE STATEMENT | |
Title | Guidebook on passive fire protection of steel structures |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Place of publication, distribution, etc | Kolkata |
Name of publisher, distributor, etc | Institute for Steel Development & Growth (INSDAG) |
Date of publication, distribution, etc | 2013 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | x,104p. |
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE | |
Title | INSDAG Publication |
Volume number/sequential designation | INS/PUB/128 |
9 (RLIN) | 58701 |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | Contents <br/>Part –I<br/>Chapter 1 : Fire Protection 1-10<br/>1.1 Introduction 1<br/>1.2 Protection Need 3<br/>1.3 Fire Types 4<br/>1.4 Fire Initiation 4<br/>1.5 Fire Protection 5<br/>1.6 Active Fire Protection 6<br/>1.6.1 Sprinklers 6<br/>1.6.2 Detectors and Alarms 7<br/>1.6.3 Smoke Control 7<br/>1.7 Passive Fire Protection 8<br/>1.8 Steel Exposed to Fire 9<br/>Chapter 2 : Passive Fire Proofing 11-23<br/>2.1 Introduction 11<br/>2.2 Major Protection Forms 13<br/>2.2.1 Spray Systems 13<br/>2.2.2 Boarded System 14<br/>2.2.3 Pre-formed System 15<br/>2.2.4 Intumescent Coating 15<br/>2.2.5 Concrete Fillings 17<br/>2.2.6 Water Fillings 17<br/>2.2.7 Other Protection Forms 17<br/>2.3 Traditional System 20<br/>2.3.1 Concrete Encasement 20<br/>2.3 .2 Composite Floor 21<br/>2.4 Fire Resistance Steel 22<br/>Chapter 3 : Protection Guidance 24-40<br/>3.1 Introduction 24<br/>3.2 Definition 25<br/>3.2. I Fire Resistance 25<br/>3.2.2 Fire Loads 26<br/>3.2.3 Fire Rating 26<br/>3.2.4 Section Factors 27<br/>3.3 Protection Specification 31<br/>3.3.1 Fire Compartment 31<br/>3.3.2 Frame and Building Envelope 33<br/>3.3.3 Fire Stopper 34<br/>3.3.4 Glazing System 34<br/>3.3.5 Fire Doors 34<br/>3.3.6 Tubular Structures 35<br/>3.4 Protection ofBuilding System 35<br/>3.4.1 Steel Construction 35<br/>3.4.2 Concrete Construction 36<br/>3.4.3 Composite Members 36<br/>3.4.4 Slim Floor Systems 37<br/>3.4.5 Reinforced Concrete Filled 37 ~<br/>3.4.6 Columns within Walls 37<br/>3.4.7 External Columns 37<br/>3.4.8 Water Filled Stryctures 38<br/>3.5 Protection not Required 39<br/>3.5.1 Shielded Members 39<br/>3.5.2 Low Fire Risk Buildings 39<br/>3.5.3 Platform Floor (access or raised floor) 39<br/>3.5.4 Raised Strong Floors 39<br/>3.5.5 Other Areas 39<br/>3.6 Re-Use ofFire Damaged Steel 40<br/>Chapter 4 : Standards and Coating Applications 41-48<br/>4.1 Introduction 41 <br/>4.2 Fire Test Standards 41<br/>4.2.1 European Standards 43<br/>4.2.2 Indian Statndards 43<br/>4.3 Assessment of Materials 45<br/>4.4 Application of Coatings 45<br/>4.4.1 Surface Preparation 45<br/>4.4.2 Primer Selection 46<br/>4.4.3 Compatibility between Coats 46<br/>4.4.4 Film Thickness 46<br/>4.5 Guidance for Applications 47 <br/>4.5.1 Application Methods 47<br/>4.5.2 Film Thickness Determination 47 3.4<br/>4.6 Acceptance and Maintenance of Coating 48<br/>Chapter 5 : Fire Testing for Pasive Protections 49-54<br/>5.1 Introduction 49<br/>5.2 Fire Testing and Certification 49 <br/>5.3 Fire Testing 50 j <br/>5.3.1 Protection System 50<br/>5.3.2 Test Specimen 50 <br/>5.3.3 Thermo Coupling 51<br/>5.3.4 Test Conditions 51 <br/>5.3.5 Results 51<br/>5.4 Product Specifications 52<br/>5.4 .1 Mixing 52<br/>5.4.2 Airless Spray 52<br/>5.4.3 Procedure 53 <br/>5.4.4 Over Spray 53<br/>5.4.5 Acceptance Criteria 53<br/>5.4.6 Correction Procedure 53<br/>5.4.7 Thickness ofTop Coat 53<br/>5.5 Cosmetic Finish 54<br/>5.6 Inspection and Maintenance 54<br/>Chapter 6 : Testing of Indian Steel Sections 55-69<br/>6.1 Introduction 55<br/>6.2 Test Set up 56<br/>6.3 Fire Test Standards 59<br/>6.3.1 Assessment Methods 59<br/>6.3.2 Certification 59<br/>6.4 Thickness of Coating 60<br/>6.5 Limiting Steel Temperature 60<br/>6.6 Estimation of Coating Systems 61<br/>6. 7 Fire Testing 62<br/>6.7.1 Coating Systems 62<br/>6.7.2 Sample Preparation 63<br/>6.8 Post Bum: Film/Char Thickness 65<br/>6.9 Summary 68<br/>Part- lll<br/>Chapter 7 : Indian Case Studies 70-78<br/>7.1 Introduction 70<br/>7.2 Ban galore International Airport 70<br/>7.3 Passenger Terminal Building, Delhi 71<br/>7.4 ETL Mall, Coimbatore 71<br/>7~5 Flextronics Mobile Hardware Manufacturing unit, Chennai 72<br/>7.6 ICICI Corporate Building Hyderabad 72<br/>7.7 Infosys Corporate Building, Pune 73<br/>7.8 Motorola Mobile Manufacturing unit, Chennai. 73<br/>7.9 Mumbai Airport Expansion, Mumbai 74<br/>7.10 Nokia Mobile Manufacturing unit- Phase I, Chennai 74<br/>7.1! Nokia Mobile Manufacturing unit- Phase II, Chennai 75<br/>7.12 Nokia Mobile Manufacturing unit-Phase III, Chennai 75<br/>7.13 Nokia Siemens Networks, Chennai 76<br/>7.14 Sacomp Charger Facility, Chennai 76<br/>7.15 DMRC Phase II, Delhi 77<br/>7.16 ICCCL, Corporate Office Building Chennai 77<br/>7.18 Volvo Eicher Corporate Office Building-Gurgaon 78<br/>Chapter 8 : Steel Section Property Tables 79-92<br/>8.1 Tata Steel Hollow Sections Property Tables 79<br/>8.1.1 Guidance ofPassive Fire Proofing (SHS Four Sides) 80<br/>8.1 .2 Guidance of Passive Fire Proofing (RHS Four Sides) 82<br/>8.1.3 Guidance ofPassive Fire Proofing (CHS) 84<br/>8.2 M/s. Jindal Steel & Power Ltd. Steel Sections property Tables (Beams) 85<br/>8.2.1 Guidance ofPassive Fire Proofing (3 Sided Beams) 86<br/>8.3 M/s. Jindal Steel & Power Ltd. Steel Sections Property Tables 88<br/>(Columns at 4 Sided Exposure)<br/>8.3.1 Guidance ofPassive Fire Proofing (4 Sided Columns) 89<br/>8.4 M/s. Rashtriya I spat Nigam Ltd. Property Table (Beams & Columns) 91<br/>8.4.1 Guidance ofPassive Fire Proofing (3 Sided Beams) 91<br/>8.4.2 Guidance ofPassive Fire Proofing (4 Sided Columns) 92<br/>Glossary 93-93<br/>Bibliography 94-95<br/> |
600 ## - SUBJECT ADDED ENTRY--PERSONAL NAME | |
9 (RLIN) | 59553 |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | FT |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Cost, normal purchase price | Total Checkouts | Full call number | Barcode | Date last seen | Date last borrowed | Cost, replacement price | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | Faculty of Technology | CEPT Library | CEPT Library | 31/12/2018 | INSDAG | 1053.00 | 1 | 693.7 SAH | 017906 | 19/01/2019 | 13/01/2019 | 1000.00 | 24/02/2017 | Book |