Image from Google Jackets

An assessment of cooling loads in commercial buildings due to Urban Heat Islands:A study of the central business district of Ahmedabad (Softcopy is also available)

By: Contributor(s): Material type: TextTextPublication details: 2022Description: ix,31pDDC classification:
  • MBEP TH-0063 TIW
Contents:
Contents Declaration ii Approval iii Abstract iv Acknowledgment v List of Figures viii List of Tables viii Abbreviations ix Definitions ix Introduction 1 a) Background 1 b) Purpose Statement 2 c) Research Question 3 d) Research Objective 3 e) Significance of the study 3 Literature Review 4 Urban Heat Islands and Urban Geometry: 5 Impacts of the UHI effect on the energy demand of buildings: 7 Existing methods of modeling UHI Intensities 7 Validation Of Urban Weather Generator and Simulation Model: 9 Urban Building Energy Model 9 Urban Building Energy Modeling: Introduction 9 Overview of UBEM developed for CBD of Ahmedabad and Simulations for Cooling EUI Projections 10 Research Methodology 10 Case Study 11 Future Weather Predictions 11 UBEM Modelling and simulation of UHI Intensities 12 Workflow and Input Data for Urban Weather Generator 13 Parameter Variability: Sensitivity Analysis 16 Results: 18 Cooling Energy Consumption of CBD area: 18 Cooling Energy Consumption of Building archetypes 19 Cooling Energy Consumption of commercial buildings 19 Impact of RCP 8.5 Emissions + UHI Intensities on Cooling EUI of a commercial building 20 Conclusions 20 Limitations of the study 21 Bibliography 22 Annexures 27 Annexure 1: Construction Properties for the baseline UBEM 27 Annexure 2: Urban Weather Generator Components 28 Annexure 3: Cooling Energy Consumption Data Sheet 28 NO RCP 8.5 Emission and no UHI Intensities 28 Only UHI Scenario 28 RCP 8.5 Emission and UHI Intensities Scenario 29 Energy Consumption of Commercial building for each urban weather scenario 29 Annexure 4 30 Office Building with ECBC prescribed envelope: 30 ECBC Building Specifications 31
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode Item holds
Thesis CEPT Library Faculty of Technology MBEP TH-0063 TIW Not For Loan 024247
Total holds: 0

Contents
Declaration ii
Approval iii
Abstract iv
Acknowledgment v
List of Figures viii
List of Tables viii
Abbreviations ix
Definitions ix
Introduction 1
a) Background 1
b) Purpose Statement 2
c) Research Question 3
d) Research Objective 3
e) Significance of the study 3
Literature Review 4
Urban Heat Islands and Urban Geometry: 5
Impacts of the UHI effect on the energy demand of buildings: 7
Existing methods of modeling UHI Intensities 7
Validation Of Urban Weather Generator and Simulation Model: 9
Urban Building Energy Model 9
Urban Building Energy Modeling: Introduction 9
Overview of UBEM developed for CBD of Ahmedabad and Simulations for Cooling EUI Projections 10
Research Methodology 10
Case Study 11
Future Weather Predictions 11
UBEM Modelling and simulation of UHI Intensities 12
Workflow and Input Data for Urban Weather Generator 13
Parameter Variability: Sensitivity Analysis 16
Results: 18
Cooling Energy Consumption of CBD area: 18
Cooling Energy Consumption of Building archetypes 19
Cooling Energy Consumption of commercial buildings 19
Impact of RCP 8.5 Emissions + UHI Intensities on Cooling EUI of a commercial building 20
Conclusions 20
Limitations of the study 21
Bibliography 22
Annexures 27
Annexure 1: Construction Properties for the baseline UBEM 27
Annexure 2: Urban Weather Generator Components 28
Annexure 3: Cooling Energy Consumption Data Sheet 28
NO RCP 8.5 Emission and no UHI Intensities 28
Only UHI Scenario 28
RCP 8.5 Emission and UHI Intensities Scenario 29
Energy Consumption of Commercial building for each urban weather scenario 29
Annexure 4 30
Office Building with ECBC prescribed envelope: 30
ECBC Building Specifications 31

There are no comments on this title.

to post a comment.
Excel To HTML using codebeautify.org Sheet Name :- Location Chart
Location Chart Basement 1 (B1) Class No. 600 - 649, 660 - 699
(B1) :Mezzanine 1 Class No. 700 - 728
(B1) :Mezzanine 2 Class No. 728.1 - 799, 650 - 659, Reference Books, Faculty work
Basement 2 (B2) Class No. 000 - 599, 800-999
Basement 3 (B3) (Please Inquire at the Counter for resources) Theses, Students' works, Bound Journals, Drawings, Atlas, Oversize Books, Rare Books, IS codes, Non-book Materials