Image from Google Jackets

Survival of Kedarnath temple : through the eyes of structural consultant - How it was built? How it sustained? How vulnerable is temple to disasters?

By: Publication details: New Delhi Structural health & disaster prevention foundation 2019Description: 108,ipISBN:
  • 9788194176800
Subject(s): DDC classification:
  • 726.145095451 BHA
Contents:
Contents Kedar Valley Details Environment & Climate Probable reason of Natural Disaster General Description of Kedarnath Temple Preble of Kedarnath Temple Architectural & Structural Features of Temple Building Elements of Kedarnath Temple Plan of Kedarnath Temple Elevation of Kedarnath Temple Construction Techniques Structural systems of the Temple Order of Construction Doagnosis & Structural Audit Introduction : Diagnosis approach for Structural Audit Detailed Foundation Evaluation by Geophysical Investigation Silt (Foreign materials) deposit analysis Characterization of materials Post Disaster Investigation Comparative analysis between Pre & Past disaster condition of temple Stability & Durability Assessment of Temple An approach for structural adequacy analysis How it sustained
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode Item holds
Book CEPT Library BK 726.145095451 BHA Available 023751
Total holds: 0

Contents
Kedar Valley Details
Environment & Climate
Probable reason of Natural Disaster
General Description of Kedarnath Temple
Preble of Kedarnath Temple
Architectural & Structural Features of Temple
Building Elements of Kedarnath Temple
Plan of Kedarnath Temple
Elevation of Kedarnath Temple
Construction Techniques
Structural systems of the Temple
Order of Construction
Doagnosis & Structural Audit
Introduction : Diagnosis approach for Structural Audit
Detailed Foundation Evaluation by Geophysical Investigation
Silt (Foreign materials) deposit analysis
Characterization of materials
Post Disaster Investigation
Comparative analysis between Pre & Past disaster condition of temple
Stability & Durability Assessment of Temple
An approach for structural adequacy analysis
How it sustained

There are no comments on this title.

to post a comment.
Excel To HTML using codebeautify.org Sheet Name :- Location Chart
Location Chart Basement 1 (B1) Class No. 600 - 649, 660 - 699
(B1) :Mezzanine 1 Class No. 700 - 728
(B1) :Mezzanine 2 Class No. 728.1 - 799, 650 - 659, Reference Books, Faculty work
Basement 2 (B2) Class No. 000 - 599, 800-999
Basement 3 (B3) (Please Inquire at the Counter for resources) Theses, Students' works, Bound Journals, Drawings, Atlas, Oversize Books, Rare Books, IS codes, Non-book Materials