Image from Google Jackets

Determining suitable daylight redirecting systems for office buildings : Chennai (Softcopy is also available )

By: Contributor(s): Material type: TextTextPublication details: 2018Description: 81pDDC classification:
  • MIAD TH-0140 MON
Contents:
CONTENTS Abstract 5 List of Figures 8 Acknowledgement 11 Overview of this research: 12 1. INTRODUCTION 13 Background 14 Purpose of the study 16 Retrofitting of the daylighting systems in office buildings 16 Research question 16 Objectives 17 Significance of the study 17 Scope and limitations 18 Hypothesis 18 2. Literature study 19 Climatic data 20 Daylight Redirecting Systems 22 Introduction 22 Vertical pipes: 23 Horizontal pipes 23 Light shelves 23 Anidolic duct system: 26 Daylighting Metrics 29 Daylight factor 29 Dynamic daylight metrics 30 Daylight Autonomy 30 Spatial daylight autonomy (sDA) 30 Useful Daylight illuminance (UDI): 30 Annual sun exposure 31 Review 31 3. Methodology 32 Simulation Guidelines 34 Validated Tool for Simulation 35 Building Data 36 Simulation set up 38 4. Simulations 41 Parameters 42 Base Case Model 43 Case 2: With Anidolic duct 45 Case 3: With both the systems 46 5. Analysis and Observations 47 Performance of each devices: 48 Performance of light shelves and anidolic ducts for each orientation: 56 6. Conclusion 58 Further research 59 Nomenclature 60 BIBLIOGRAPHY 61 APPENDIX 64
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode Item holds
Thesis CEPT Library Faculty of Design MIAD TH-0140 MON Not for loan 019733
Total holds: 0

CONTENTS
Abstract 5
List of Figures 8
Acknowledgement 11
Overview of this research: 12
1. INTRODUCTION 13
Background 14
Purpose of the study 16
Retrofitting of the daylighting systems in office buildings 16
Research question 16
Objectives 17
Significance of the study 17
Scope and limitations 18
Hypothesis 18
2. Literature study 19
Climatic data 20
Daylight Redirecting Systems 22
Introduction 22
Vertical pipes: 23
Horizontal pipes 23
Light shelves 23
Anidolic duct system: 26
Daylighting Metrics 29
Daylight factor 29
Dynamic daylight metrics 30
Daylight Autonomy 30
Spatial daylight autonomy (sDA) 30
Useful Daylight illuminance (UDI): 30
Annual sun exposure 31
Review 31
3. Methodology 32
Simulation Guidelines 34
Validated Tool for Simulation 35
Building Data 36
Simulation set up 38
4. Simulations 41
Parameters 42
Base Case Model 43
Case 2: With Anidolic duct 45
Case 3: With both the systems 46
5. Analysis and Observations 47
Performance of each devices: 48
Performance of light shelves and anidolic ducts for each orientation: 56
6. Conclusion 58
Further research 59
Nomenclature 60
BIBLIOGRAPHY 61
APPENDIX 64

There are no comments on this title.

to post a comment.
Excel To HTML using codebeautify.org Sheet Name :- Location Chart
Location Chart Basement 1 (B1) Class No. 600 - 649, 660 - 699
(B1) :Mezzanine 1 Class No. 700 - 728
(B1) :Mezzanine 2 Class No. 728.1 - 799, 650 - 659, Reference Books, Faculty work
Basement 2 (B2) Class No. 000 - 599, 800-999
Basement 3 (B3) (Please Inquire at the Counter for resources) Theses, Students' works, Bound Journals, Drawings, Atlas, Oversize Books, Rare Books, IS codes, Non-book Materials