Potential of combined passive & low energy cooling systems for Indian office buildings under current and future climatic conditions (Softcopy is also available) (Record no. 72517)

MARC details
000 -LEADER
fixed length control field 02347nam a2200181Ia 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 240829s9999 xx 000 0 und d
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number MBEP TH-0107
Item number SAW
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Sawant, Tamanna Nitin (PBE22362)
245 #0 - TITLE STATEMENT
Title Potential of combined passive & low energy cooling systems for Indian office buildings under current and future climatic conditions (Softcopy is also available)
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc 2024
300 ## - PHYSICAL DESCRIPTION
Extent xvi,36p.
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note Table Of Contents <br/>Abstract Iii <br/>Undertaking V <br/>Certificate Vii <br/>Acknowledgements Ix <br/>Table Of Contents Xi <br/>List Of Figures & Tables Xiii <br/>List Of Abbreviations Xv <br/>Chapter-1: Introduction 1 <br/>1.1 Background And Context 1 <br/>1.2 Purpose 2 <br/>1.3 Research Questions 2 <br/>1.4 Research Objectives 2 <br/>1.5 Significance Of The Study 2 <br/>1.6 Scope And Limitations Of The Study 3 <br/>Chapter-2: Literature Review 4 <br/>2.1 Scope Of The Literature Review 4 <br/>2.1.1 Understanding The Passive & Low Energy Cooling Systems And Current Assessments Carried Out For The Same. 4 <br/>2.1.2 Potential Of Passive And Low Energy Cooling Systems With Respect To Future Weather Conditions. 6 <br/>2.2 Relevance Of The Study 6 <br/>Chapter-3: Research Methodology 8 <br/>3.1 Baseline Study Model Input Parameters 9 <br/>3.2 Weather Data Collection And Representative Cities 11 <br/>3.3 Model Verification 11 <br/>3.4 Thermal Comfort Model 12 <br/>3.5 Simulation Scenarios 13 <br/>3.6 Passive And Low Energy Systems Modelling Conditions. 14 <br/>Chapter-4: Results And Discussion 15 <br/>4.1 Base Case (Variable Set Point) Assessment. 15 <br/>4.2 Preliminary Assessment To Understand The Extent Of Selected Low Energy Cooling Systems. 16 <br/>4.2.1 Eahe 16 <br/>4.2.2 Evaporative Cooling (Iec And Dec) 17 <br/>4.3 Comparative Assessment Of Individual Application Of Selected Passive & Low Energy Cooling Systems. 19 <br/>4.3.1 Energy Use Intensity (Eui) Variation 19 <br/>4.3.2 Hvac Sizing Variation 21 <br/>4.4 Comparative Assessment Of Combined Application Of Selected Passive & Low Energy Cooling Systems. 24 <br/>4.5 Future Scenario. 27 <br/>Chapter-5: Conclusion 28 <br/>References 30 <br/>Appendix 35 <br/>Annexure A 35 <br/>
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Damle, Rashmin Mohan (Guide)
890 ## - Country
Country India
891 ## - Topic
Topic 2022 Batch
891 ## - Topic
Topic FT-PG
891 ## - Topic
Topic Masters of Technology in Building Energy Performance
Holdings
Withdrawn status Lost status Damaged status Not for loan Collection code Withdrawn status Home library Current library Date acquired Source of acquisition Full call number Barcode Date last seen Price effective from Koha item type
      Not For Loan Faculty of Technology   CEPT Library CEPT Library 29/08/2024 Faculty of Technology MBEP TH-0107 SAW 026648 29/08/2024 29/08/2024 Thesis
Excel To HTML using codebeautify.org Sheet Name :- Location Chart
Location Chart Basement 1 (B1) Class No. 600 - 649, 660 - 699
(B1) :Mezzanine 1 Class No. 700 - 728
(B1) :Mezzanine 2 Class No. 728.1 - 799, 650 - 659, Reference Books, Faculty work
Basement 2 (B2) Class No. 000 - 599, 800-999
Basement 3 (B3) (Please Inquire at the Counter for resources) Theses, Students' works, Bound Journals, Drawings, Atlas, Oversize Books, Rare Books, IS codes, Non-book Materials