Early design approach for ensuring visual comfort using optimized shading for office buildings (Softcopy is also available) (Record no. 72514)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02265nam a2200181Ia 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 240829s9999 xx 000 0 und d |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | MBEP TH-0104 |
Item number | ARO |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Arora, Mokshika (PBE22202) |
245 #0 - TITLE STATEMENT | |
Title | Early design approach for ensuring visual comfort using optimized shading for office buildings (Softcopy is also available) |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc | 2024 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | ix,39p. |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | Table Of Contents <br/>Abstract I <br/>Undertaking Ii <br/>Certificate Iii <br/>Acknowledgements Iv <br/>Abbreviations V <br/>Table Of Contents Vi <br/>List Of Figures Vii <br/>List Of Tables Ix <br/>Chapter-1: Introduction 10 <br/>1.1 External Shading Device 10 <br/>1.2 Early Design Stage 11 <br/>1.3 Existing Methods 11 <br/>1.4 Material Selection 12 <br/>1.5 Aim & Reliability. 12 <br/>Chapter-2: Literature Review 13 <br/>2.1 Indian Standards & Existing Daylight Metrices: 13 <br/>2.1.1 Projection Factor 13 <br/>2.1.2 Glare Metrics. 14 <br/>2.1.3 Daylight Access: 14 <br/>2.2 Performance Quantification Of Shading Devices: 15 <br/>2.3 Basis Of Glare Mitigation Methodology: 15 <br/>2.4 Perforation Geometry Exploration 17 <br/>2.5 Existing Early Design Methods For Shading Device: 18 <br/>2.6 Multi-Dimensional Approach For Shading Devices. 18 <br/>2.7 Summary 18 <br/>Chapter-3: Methodology 19 <br/>3.1 Input Parameters: 19 <br/>3.1.1 Constants: 20 <br/>3.1.2 Variables: 21 <br/>3.2 Key Performance Indexes (As An After Check): 21 <br/>3.3 Base Case (No Shading): 22 <br/>3.4 Step 1 (Base Overdesigned Geometry-Ecbc Compliant): 22 <br/>3.5 Step 2 (Optimising Geometry With Shaderade): 23 <br/>3.6 Step 3 (Projecting Guth Position Index For Visual Comfort): 26 <br/>3.7 Step 5 (Overlapping Results & Introducing Perforations): 27 <br/>3.7.1 Method Of Creating Openness Ratio/Percentage In Shading Device 28 <br/>3.8 Summarizing Methodolgy 28 <br/>Chapter-4: Results 29 <br/>4.1 Thermal Performance 29 <br/>4.2 Dgp V/S Da 30 <br/>4.3 Physical Model 31 <br/>4.4 Lightstanza Results 32 <br/>4.5 Inter-City Comparison 34 <br/>4.5.1 South Orientation 34 <br/>Chapter-5: Conclusion 35 <br/>References 37 <br/>Appendix 39 <br/>Appendix A 39 <br/> |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Agarwal, Minu (Guide) |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | 2022 Batch |
891 ## - Topic | |
Topic | FT-PG |
891 ## - Topic | |
Topic | Masters of Technology in Building Energy Performance |
Withdrawn status | Lost status | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|