Performance-driven cleaning frequency of vertical glazing units (Softcopy is also available) (Record no. 71192)

MARC details
000 -LEADER
fixed length control field 02474nam a2200181Ia 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230825s9999||||xx |||||||||||||| ||und||
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number MBEP TH-0078
Item number TIK
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Tikar, Anjali (PBE21041)
245 #0 - TITLE STATEMENT
Title Performance-driven cleaning frequency of vertical glazing units (Softcopy is also available)
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc 2023
300 ## - PHYSICAL DESCRIPTION
Extent xii,51p.
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note Table of Contents <br/>ABSTRACT i <br/>UNDERTAKING iii <br/>CERTIFICATE v <br/>ACKNOWLEDGEMENTS vii <br/>LIST OF FIGURES xi <br/>LIST OF TABLES <br/>1. INTRODUCTION 1 <br/>1.1. Aim 1 <br/>1.2. Research Question 2 <br/>1.3. Research Objective 2 <br/>1.4. Significance of Research 2 <br/>1.5. Scope 3 <br/>2. Literature STudy 5 <br/>2.1. Introduction 5 <br/>2.2. Soiling and its Impact on Glazing 5 <br/>2.3. Dust Deposition and Daylight Transmittance: Factors and Findings 6 <br/>2.4. Impact of Dust Accumulation on Visual Clarity and Perception 7 <br/>3. Research Methodology 9 <br/>3.1. Harvesting Samples of soiled glass 9 <br/>3.2. Measurement of light transmission Properties 10 <br/>3.2.1. Spectrophotometer 10 <br/>3.2.2. Light Transmission Box Instrument. 11 <br/>3.3. Test room Experiment for Visual Clarity with Dust Perception. 13 <br/>3.3.1. Test Facility 13 <br/>3.3.2. Experimental procedure and studied parameter 15 <br/>3.3.3. Questionnaire used for data collection. 16 <br/>3.4. Harvesting Samples of soiled glass 17 <br/>3.5. Measurement of light transmission Properties 18 <br/>3.5.1. Spectrophotometer 18 <br/>3.5.2. Light Transmission Box Instrument. 19 <br/>3.6. Test room Experiment for Visual Clarity with Dust Perception. 20 <br/>3.6.1. Test Facility 20 <br/>3.6.2. Experimental procedure and studied parameter 22 <br/>3.6.3. Questionnaire used for data collection. 23 <br/>4. Result and Discussions 25 <br/>4.1. Impact of particle deposition on light transmission properties. 25 <br/>4.1.1. Light Transmittance Measurement 25 <br/>4.1.2. Haze formation (Images and Description) 28 <br/>4.2. Visual Clarity with Dust Accumulation over time 29 <br/>4.2.1. Observation and Interpretation (total score and descriptive statistic) 29 <br/>4.2.2. Analysis with variance result. 34 <br/>5. Implication of operational frequency of cleaning 37 <br/>5.1. Sensitivity Analysis 38 <br/>5.2. Optimization Cases 39 <br/>6. conclusion 41 <br/>References 43 <br/>APPENDIX 45<br/><br/>
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Agrawal, Minu (Guide)
890 ## - Country
Country India
891 ## - Topic
Topic 2021 Batch
891 ## - Topic
Topic FT-PG
891 ## - Topic
Topic Masters of Technology in Building Energy Performance
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Withdrawn status Home library Current library Date acquired Source of acquisition Full call number Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification   Not For Loan Faculty of Technology   CEPT Library CEPT Library 25/08/2023 Faculty of Technology MBEP TH-0078 TIK 025212 25/08/2023 25/08/2023 Thesis
Excel To HTML using codebeautify.org Sheet Name :- Location Chart
Location Chart Basement 1 (B1) Class No. 600 - 649, 660 - 699
(B1) :Mezzanine 1 Class No. 700 - 728
(B1) :Mezzanine 2 Class No. 728.1 - 799, 650 - 659, Reference Books, Faculty work
Basement 2 (B2) Class No. 000 - 599, 800-999
Basement 3 (B3) (Please Inquire at the Counter for resources) Theses, Students' works, Bound Journals, Drawings, Atlas, Oversize Books, Rare Books, IS codes, Non-book Materials