Comparative testing of BQEET (Building Energy Estimation Tool) that quantifies the reduction in cooling energy due to passive strategies for 59 Indian cities (Softcopy is also available) (Record no. 56564)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 01990nam a2200181 4500 |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | MBEP TH-0024 |
Item number | PAT |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Pathella, Sanchi (PT500917) |
245 ## - TITLE STATEMENT | |
Title | Comparative testing of BQEET (Building Energy Estimation Tool) that quantifies the reduction in cooling energy due to passive strategies for 59 Indian cities (Softcopy is also available) |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc | 2019 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | xviii,ii,30,xiiip. |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | Table of Content<br/>Introduction 1<br/>Literature Review 4<br/>Scope of testing 5<br/>Cases for testing 5<br/>Metrics for testing 6<br/>Location for testing 6<br/>Research Methodology 10<br/>Comparison of results of L100ALWitte and L100ALPathella 11<br/>Simplifying inputs for L100ALPathella 11<br/>Modifications to L100ALPathella Simplified 12<br/>Developing Indianised version of L100ALPathella Modified - I100A 12<br/>Review of building physics in EnergyPlus 13<br/>Review of building physics in the TM41 CIBSE method based on cooling degree days 13<br/>Implementation of TM41 CIBSE method in BQEET 13<br/>Modification needed in BQEET 13<br/>Comfort Cooling 13<br/>Night Cooling 13<br/>Evaporative Cooling 14<br/>Comparison of BQEET and EnergyPlus results for I100A with passive strategies 14<br/>Results and Analysis 15<br/>Comparison of results of L100ALWitte and L100ALPathella 15<br/>Simplifying inputs for L100ALPathella 15<br/>Modifications to L100ALPathella Simplified 16<br/>Developing the Indianised base case - I100A 16<br/>Review of building physics in EnergyPlus 19<br/>Fabric gain due to conduction through the wall, window and roof 21<br/>Solar gain due to radiation through the window 22<br/>Casual gain due to occupancy 22<br/>Latent gain due to infiltration and occupancy 22<br/>Fan gain 23<br/>Mitigation of gains due to night time cooling of the fabric 24<br/>Comfort Cooling 27<br/>Night Cooling 28<br/>Evaporative Cooling 29<br/>Conclusions 30<br/>References i<br/> |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Vaidya, Prasad (Guide) |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | FT-PG |
891 ## - Topic | |
Topic | 2017 Batch |
891 ## - Topic | |
Topic | Masters of Technology in Building Energy Performance |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | Faculty of Technology | CEPT Library | CEPT Library | 08/08/2019 | Faculty of Technology | MBEP TH-0024 PAT | 021361 | 08/08/2019 | 08/08/2019 | Thesis |