Analysis of flow patterns using water-table apparatus by varying the model scale (Softcopy is also available) (Record no. 56560)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02146nam a2200181 4500 |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | MBEP TH-0020 |
Item number | CHA |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Chawan, Vijay Kumar (PT500517) |
245 ## - TITLE STATEMENT | |
Title | Analysis of flow patterns using water-table apparatus by varying the model scale (Softcopy is also available) |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc | 2019 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | xvi,ii,31,ixp. |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | CONTENTS<br/>1.Introduction 1 <br/>1.1.Background 1 <br/>1.2.Purpose statement 2 <br/>1.3.Research question 2 <br/>1.4.Research objectives 2 <br/>1.5.Significance of the study 2 <br/>1.6 Scope 2 <br/>1.7.Limitations 3 <br/>2.Literature Review 3 <br/>2.1 Analytical and empirical models 3 <br/>2.2 Small-scale and full-scale experimental models 3 <br/>2.3 Multi-zone and numerical models 4 <br/>2.4.Computer fluid dynamics (CFD) 4 <br/>2.5.Water-table studies 4 <br/>2.6.Learning from the literature review 5 <br/>3.Research Methodology 6 <br/>3.1.Overview 6 <br/>3.2.Experimental Setup 6 <br/>3.3.Experimentation of different model scales 8 <br/>3.4.Testing of current methodology for different speeds 9 <br/>3.5.Testing of current methodology for ACH 9 <br/>3.6.Photographic data analysis for deriving ventilation metrics 10 <br/>3.7.Extracting Pixel values 10 <br/>3.8.Establishing relationship between pixel values and dye concentration 10 <br/>3.9.Ventilation metrics 13 <br/>3.6.1Percentage of dead spots (% DS) 13 <br/>3.6.2Absolute ventilation efficiency (Ea) 13 <br/>3.6.3Air Changes per Hour (ACH) 13 <br/>3.6.4Ventilation metric calculation 15 <br/>4.Results and discussion 16 <br/>4.1.Flow patterns for different configurations using 1:20 Scale 16 <br/>4.2.Effect of model scale 18 <br/>4.3.Dead Spots (DS) 19 <br/>4.4.Absolute Ventilation Efficiency (Ea) 23 <br/>4.5.Air Change per Hour (ACH) 25 <br/>4.6.Effect of speed at 1:20 scale 27 <br/>5. Conclusions 28 <br/>6. Learnings and Recommendations for future study 29 <br/>6.1.Learnings from the experiment 29 <br/>6.2.Recommendations 29 <br/>7 References 30 <br/>Appendix A1 I <br/>Appendix A2 II <br/>Appendix B III <br/>Appendix C IV <br/>Appendix D VI <br/>Appendix E IX <br/><br/> <br/> |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Damle, Rashmin (Guide) |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | FT-PG |
891 ## - Topic | |
Topic | 2017 Batch |
891 ## - Topic | |
Topic | Masters of Technology in Building Energy Performance |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Source of classification or shelving scheme | Dewey Decimal Classification |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | Faculty of Technology | CEPT Library | CEPT Library | 08/08/2019 | Faculty of Technology | MBEP TH-0020 CHA | 021357 | 08/08/2019 | 08/08/2019 | Thesis |