Analysis of flow patterns using water-table apparatus by varying the model scale (Softcopy is also available) (Record no. 56560)

MARC details
000 -LEADER
fixed length control field 02146nam a2200181 4500
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number MBEP TH-0020
Item number CHA
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Chawan, Vijay Kumar (PT500517)
245 ## - TITLE STATEMENT
Title Analysis of flow patterns using water-table apparatus by varying the model scale (Softcopy is also available)
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc 2019
300 ## - PHYSICAL DESCRIPTION
Extent xvi,ii,31,ixp.
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note CONTENTS<br/>1.Introduction 1 <br/>1.1.Background 1 <br/>1.2.Purpose statement 2 <br/>1.3.Research question 2 <br/>1.4.Research objectives 2 <br/>1.5.Significance of the study 2 <br/>1.6 Scope 2 <br/>1.7.Limitations 3 <br/>2.Literature Review 3 <br/>2.1 Analytical and empirical models 3 <br/>2.2 Small-scale and full-scale experimental models 3 <br/>2.3 Multi-zone and numerical models 4 <br/>2.4.Computer fluid dynamics (CFD) 4 <br/>2.5.Water-table studies 4 <br/>2.6.Learning from the literature review 5 <br/>3.Research Methodology 6 <br/>3.1.Overview 6 <br/>3.2.Experimental Setup 6 <br/>3.3.Experimentation of different model scales 8 <br/>3.4.Testing of current methodology for different speeds 9 <br/>3.5.Testing of current methodology for ACH 9 <br/>3.6.Photographic data analysis for deriving ventilation metrics 10 <br/>3.7.Extracting Pixel values 10 <br/>3.8.Establishing relationship between pixel values and dye concentration 10 <br/>3.9.Ventilation metrics 13 <br/>3.6.1Percentage of dead spots (% DS) 13 <br/>3.6.2Absolute ventilation efficiency (Ea) 13 <br/>3.6.3Air Changes per Hour (ACH) 13 <br/>3.6.4Ventilation metric calculation 15 <br/>4.Results and discussion 16 <br/>4.1.Flow patterns for different configurations using 1:20 Scale 16 <br/>4.2.Effect of model scale 18 <br/>4.3.Dead Spots (DS) 19 <br/>4.4.Absolute Ventilation Efficiency (Ea) 23 <br/>4.5.Air Change per Hour (ACH) 25 <br/>4.6.Effect of speed at 1:20 scale 27 <br/>5. Conclusions 28 <br/>6. Learnings and Recommendations for future study 29 <br/>6.1.Learnings from the experiment 29 <br/>6.2.Recommendations 29 <br/>7 References 30 <br/>Appendix A1 I <br/>Appendix A2 II <br/>Appendix B III <br/>Appendix C IV <br/>Appendix D VI <br/>Appendix E IX <br/><br/> <br/>
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Damle, Rashmin (Guide)
890 ## - Country
Country India
891 ## - Topic
Topic FT-PG
891 ## - Topic
Topic 2017 Batch
891 ## - Topic
Topic Masters of Technology in Building Energy Performance
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Withdrawn status Home library Current library Date acquired Source of acquisition Full call number Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     Faculty of Technology   CEPT Library CEPT Library 08/08/2019 Faculty of Technology MBEP TH-0020 CHA 021357 08/08/2019 08/08/2019 Thesis
Excel To HTML using codebeautify.org Sheet Name :- Location Chart
Location Chart Basement 1 (B1) Class No. 600 - 649, 660 - 699
(B1) :Mezzanine 1 Class No. 700 - 728
(B1) :Mezzanine 2 Class No. 728.1 - 799, 650 - 659, Reference Books, Faculty work
Basement 2 (B2) Class No. 000 - 599, 800-999
Basement 3 (B3) (Please Inquire at the Counter for resources) Theses, Students' works, Bound Journals, Drawings, Atlas, Oversize Books, Rare Books, IS codes, Non-book Materials