Comparative study of structural systems for deep water RCC pile berth with respect to various oceanographic and vessel parameters (Softcopy is also available) (Record no. 55076)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02643nam a2200193Ia 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180908s9999||||xx |||||||||||||| ||und|| |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | SD TH-0224 |
Item number | CHO |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Chowdhury, Ankita Roy (PT400116) |
245 #0 - TITLE STATEMENT | |
Title | Comparative study of structural systems for deep water RCC pile berth with respect to various oceanographic and vessel parameters (Softcopy is also available) |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 136p.,25Sheets |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | CONTENTS <br/>LIST OF TABLES 4 <br/>LIST OF FIGURES 5 <br/>LIST OF CHARTS 7 <br/>ABBREVIATIONS 9 <br/>CHAPTER 1 12 <br/>Introduction 12 <br/>General. 12 <br/>Need for Study. 13 <br/>Objective. 13 <br/>Scope of Work. 15 <br/>CHAPTER 2 16 <br/>Literature Review 16 <br/>CHAPTER 3 19 <br/>Problem Formulation 19 <br/>General. 19 <br/>Methodology. 19 <br/>Data collection and geometry for RCC pile jetty 21 <br/>Structural Layout 26 <br/>Primary and secondary beams system (P – S System). 26 <br/>Cross section of jetty (P – S System) for different seismic zones and tidal details. 28<br/> All main beams system (P System). 32 <br/>Cross section of jetty (P System) for different seismic zones and tidal details. 34 <br/>Load data and load combinations 38 <br/>Dead load. 38 <br/>Live load. 38 <br/>Berthing Force. 38 <br/>Mooring Force. 42 <br/>Current Force. 43 <br/>Wave Force. 44 <br/>Hydrodynamic Force. 47 <br/>Wind Force. 49 <br/>Seismic Force. 50 <br/>Load combinations. 51 <br/>Model nomenclature and generation 52 <br/>Model nomenclature. 52 <br/>Model generation. 53 <br/>Selection of pile force evaluation 54 <br/>CHAPTER 4 56 <br/>Results and observations 56 <br/>Results <br/>Charts for comparison of design forces acting on pile for varying water depths, with respect to seismic zones, pile spacings, soil conditions, vessel types and structural systems. 57 <br/>Charts for comparison of material consumption for varying water depths, with respect to seismic zones, pile spacings, soil conditions, vessel types and structural systems. 82 <br/>Charts for comparison of lateral forces and moments acting on pile for varying wave heights, with respect to seismic zones and depths of water during high tide. 99 <br/>Charts for comparison of lateral forces and moments acting on pile for varying wave heights, with respect to seismic zones and depth of water during low tide. 104 <br/>Observations. 116 <br/>CHAPTER 5 130 <br/>Conclusions and future scopes 130 <br/>Conclusions. 130 <br/>Future scope. 135 <br/>REFERENCES 136 <br/> |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Kapasi, Sanjeev (Guide) |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Shah, Dhara (Guide) |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | 2016 Batch |
891 ## - Topic | |
Topic | FT-PG |
891 ## - Topic | |
Topic | Structural Design |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | Faculty of Technology | CEPT Library | CEPT Library | 08/09/2018 | Faculty of Technology | SD TH-0224 CHO | 019897 | 08/09/2018 | 08/09/2018 | Thesis |