Lighting retrofit of CEPT University : enhancing visual comfort and reducing energy consumption (Also available on CD) (Record no. 55074)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02449nam a2200181Ia 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180908s9999||||xx |||||||||||||| ||und|| |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | MBEP TH-0017 |
Item number | CHA |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Chaudhary, Abdul Moeed (PT500215) |
245 #0 - TITLE STATEMENT | |
Title | Lighting retrofit of CEPT University : enhancing visual comfort and reducing energy consumption (Also available on CD) |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | xvii,104p.,CD-ROM |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | CONTENTS<br/>Acknowledgement ix <br/>Abstract xi <br/>List of figures xiii <br/>List of Tables xv <br/>List of Abbreviations xvii <br/>1. Introduction 1 <br/>1.1 Background 1 <br/>1.2 Need for the project 2 <br/>1.3 Statement of purpose 2 <br/>2. Literature study 3 <br/>2.1 Energy saving opportunity with lighting retrofit 3 <br/>2.2 Non-energy benefits of good lighting 4 <br/>2.3 Lighting audit methods 4 <br/>2.4 Visual comfort survey 5 <br/>2.5 Lighting Simulation 6 <br/>2.6 Lighting best practices 7 <br/>2.7 Codes, standards, and guidelines 7 <br/>2.8 Case studies 8 <br/>2.9 Summary of literature review 9 <br/>3. Project methodology 11 <br/>3.1 Phase-I Audit: Selection of representative spaces 11 <br/>3.2 Phase-II Audit: Detailed audit of the 3 representative spaces 11 <br/>3.3 Visual comfort survey 13 <br/>3.4 Market survey 13 <br/>3.5 Proposed retrofit solutions 13 <br/>4. Analysis and Findings 17 <br/>4.1 Phase I Audit: Selection of representative spaces 17 <br/>4.2 Phase-II audit of representative spaces 17 <br/>4.2.1 Studio (FD202) 18 <br/>4.2.2 Classroom (FT 104) 20 <br/>4.2.3 Private office (FP 218) 23 <br/>4.3 Visual comfort survey 25 <br/>4.3.1 Studio (FD 202) 25 <br/>4.3.2 Classroom (FT 104) 26 <br/>4.3.3 Private office (FP218) 27 <br/>4.4 Market Survey 27 <br/>4.5 Proposed retrofit solutions 28 <br/>4.5.1 Proposal for Studio (FD202) 28 <br/>4.5.2 Proposal for classroom (FT104) 32 <br/>4.5.3 Proposal for private office (FP 218) 35 <br/>4.5.4 Summary of results 38 <br/>5. Conclusion 39 <br/>6. Future work 41 <br/>References 43 <br/>Appendices 45 <br/>Appendix A: Phase 1 Audit 45 <br/>Appendix B: Visual comfort survey form 49 <br/>Appendix C: Validation of model 55 <br/>Appendix D: Phase II Audit Documentation 57 <br/>Appendix E: Proposed Retrofit luminaires details 69 <br/>Appendix F: Proposed retrofit results 71 <br/>Appendix G: Glossary 105 <br/> |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Vaidya, Prasad (Guide) |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | 2015 Batch |
891 ## - Topic | |
Topic | FT-PG |
891 ## - Topic | |
Topic | Masters of Technology in Building Energy Performance |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | Faculty of Technology | CEPT Library | CEPT Library | 08/09/2018 | Faculty of Technology | MBEP TH-0017 CHA | 019873 | 08/09/2018 | 08/09/2018 | Thesis |