Estimation and analysis of ventilation rates in schools in indian context (Softcopy is also available) (Record no. 55070)

MARC details
000 -LEADER
fixed length control field 03338nam a2200181Ia 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180908s9999||||xx |||||||||||||| ||und||
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number MBEP TH-0013
Item number SAN
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Sandhiya, Jaykumar (PT500816)
245 #0 - TITLE STATEMENT
Title Estimation and analysis of ventilation rates in schools in indian context (Softcopy is also available)
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc 2018
300 ## - PHYSICAL DESCRIPTION
Extent xv,45p.
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note Table of Contents<br/>1. DECLARATION III <br/>2. APPROVAL V<br/>3. ACKNOWLEDGEMENT IX<br/>4. LIST OF FIGURES XIII<br/>5. LIST OF TABLES XIV<br/>6. LIST OF ABBREVIATIONS XV<br/>7. LIST OF VARIABLES XV<br/>1. INTRODUCTION AND BACKGROUND 2<br/>1.1 BACKGROUND 2<br/>1.2 SIGNIFICANCE OF THE STUDY 2<br/>2. PURPOSE STATEMENT 2<br/>2.1 RESEARCH QUESTIONS 3<br/>2.1.1 Primary research question 3<br/>2.1.2 Secondary research question 3<br/>2.2 RESEARCH OBJECTIVE 3<br/>3. LITERATURE REVIEW 4<br/>3.1 IMPORTANCE OF IAQ TO HUMAN HEALTH 4<br/>3.2 NEED FOR THE STUDY 4<br/>3.3 ASSOCIATION OF VENTILATION RATES AND CO2 CONCENTRATION WITH STUDENT’S ACADEMIC PERFORMANCE AND<br/>HEALTH-INTERNATIONAL STUDIES 4<br/>3.4 STUDIES RELEVANT TO RESEARCH METHODOLOGY 7<br/>3.4.1 Onsite procedure 7<br/>3.4.2 Application of metabolic rate in ventilation study 7<br/>3.4.3 Estimation of ventilation rates 7<br/>4. RESEARCH METHODOLOGY 8<br/>4.1 OVERVIEW- 8<br/>4.2 APPROACH AND OBJECTIVE OF FIELD MEASUREMENTS 8<br/>4.3 IDENTIFYING AND RECRUITING SCHOOLS 8<br/>4.4 INSTRUMENTATION AND MEASUREMENTS 9<br/>4.5 LAB CALIBRATION OF CO2 LOGGER 10<br/>4.6 FIELD MEASUREMENTS 12<br/>4.6.1 Field details 12<br/>4.6.2 Measurement Setup 13<br/>4.6.3 Daily monitoring procedure: 14<br/>4.7 APPLICATION OF THEORY 15<br/>4.7.1 Introduction 15<br/>4.7.2 Estimating air flow from Css (Q1) 15<br/>4.7.3 Estimating Ventilation Rates-Using Air Speed Measurements (alternate flow measurements)-Q2 16<br/>5. RESULTS AND ANALYSIS 18<br/>5.1 VENTILATION RATES IN AHMEDABAD CLASSROOMS 18<br/>5.2 MEASURED PARAMETERS OF INDOOR AND OUTDOOR CO2 CONCENTRATION, TEMPERATURE, RH AND PARTICULATE MATTER 19<br/>5.2.1 CO2 concentration 19<br/>5.2.2 Temperate and RH 20<br/>5.2.3 Particulate Matter 20<br/>5.3 COMPARISON OF Q1 AND Q2 21<br/>5.4 COMPARISON OF VR OF AHMEDABAD CLASSROOM TO INTERNATIONAL STUDIES 21<br/>5.5 COMPARISON OF VR OF AHMEDABAD CLASSROOM TO ASHRAE (2016) AND BUREAU OF INDIAN STANDARDS (2016) 22<br/>6. CONCLUSION 24<br/>7. FUTURE SCOPE: 25<br/>8. REFERENCES 26<br/>9. ANNEXURE 28<br/>A. IDENTIFYING AND RECRUITING SCHOOLS 28<br/>B. CALIBRATION 29<br/>B.1. SPECIFICATION OF THE COMPRESSED CO2 CYLINDER 29<br/>B.2. ESTIMATION OF THE CALIBRATION ERROR 29<br/>C. DETAILS OF INTERVIEW 31<br/>D. SCHOOLS DESCRIPTION 32<br/>E. NON-LINEAR CURVE FITTING USING SOLVER 35<br/>F. DATA 36<br/>F.1. VELOCITY MEASUREMENT 36<br/>F.1.1. SCHOOL C 37<br/>F.1.2. SCHOOL D 37<br/>F.2. CO2 MEASUREMENTS IN EACH CLASSROOM 38<br/>F.2.1. SCHOOL A: CLASSROOM 38<br/>F.2.2. SCHOOL A: CLASSROOM 2 39<br/>F.2.3. SCHOOL B: CLASSROOM 1 40<br/>F.2.4. SCHOOL B: CLASSROOM 2 40<br/>F.2.5. SCHOOL C: CLASSROOM 1 41<br/>F.2.6. SCHOOL C: CLASSROOM 2 42<br/>F.2.7. SCHOOL D: CLASSROOM 1 42<br/>F.2.8. SCHOOL D: CLASSROOM 2 43<br/>F.2.9. SCHOOL E: 44<br/>F.2.10. SCHOOL F: CLASSROOM 1 44<br/>F.2.11. SCHOOL F: CLASSROOM 2 45<br/>
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Apte, Michael (Guide)
890 ## - Country
Country India
891 ## - Topic
Topic 2016 Batch
891 ## - Topic
Topic FT-PG
891 ## - Topic
Topic Masters of Technology in Building Energy Performance
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Withdrawn status Home library Current library Date acquired Source of acquisition Full call number Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     Faculty of Technology   CEPT Library CEPT Library 08/09/2018 Faculty of Technology MBEP TH-0013 SAN 019869 08/09/2018 08/09/2018 Thesis
Excel To HTML using codebeautify.org Sheet Name :- Location Chart
Location Chart Basement 1 (B1) Class No. 600 - 649, 660 - 699
(B1) :Mezzanine 1 Class No. 700 - 728
(B1) :Mezzanine 2 Class No. 728.1 - 799, 650 - 659, Reference Books, Faculty work
Basement 2 (B2) Class No. 000 - 599, 800-999
Basement 3 (B3) (Please Inquire at the Counter for resources) Theses, Students' works, Bound Journals, Drawings, Atlas, Oversize Books, Rare Books, IS codes, Non-book Materials