Experimental investigation of the terracotta tubes based direct evaporative cooling system (Softcopy is also available) (Record no. 55068)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03476nam a2200181Ia 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180908s9999||||xx |||||||||||||| ||und|| |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | MBEP TH-0011 |
Item number | PRI |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Priyadarshi, Sahil (PT500716) |
245 #0 - TITLE STATEMENT | |
Title | Experimental investigation of the terracotta tubes based direct evaporative cooling system (Softcopy is also available) |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | xi,42p. |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | Content <br/>List of Abbreviations x <br/>Definitions of Terminology xi <br/>1 Introduction - 1 - <br/>Background - 1 - <br/>1.1.1 Purpose of installation - 1 - <br/>1.1.2 Cool AnT System Description & Working Principle - 1 - <br/>1.1.3 System Limitation - 2 - <br/>1.1.4 Need for the study - 2 - <br/>Research Question - 2 – <br/>1.2.1 Research objectives - 2 - <br/>Significance of the study - 3 - <br/>2 Literature Review - 3 - <br/>Introduction - 3 - <br/>Material Relevance - 3 - <br/>Summary of literature review - 7 - <br/>3 Research Methodology - 8 - <br/>Overview - 8 - <br/>Experimental Set-up - 8 - <br/>3.2.1 Fabrication - 8 - <br/>Measurements - 10 - <br/>3.3.1 Measured Parameters - 10 - <br/>3.3.2 Measuring Instruments & Equipment Specifications - 10 - <br/>3.3.3 Measurement Methodology - 11 - <br/>Experimentation Methodology - 12 - <br/>3.4.1 Fully saturated pots without water flow at different air flow rates - 12 - <br/>3.4.2 Dry pots with water flow at different air flow rates - 13 - <br/>3.4.3 Dry pots at different water flow rates - 13 - <br/>3.4.4 Geometrical Variation - 13 - <br/>Data Gathering Process - 13 - <br/>Data Analysis - 14 - <br/>Experimentation Guidelines - 14 - <br/>3.7.1 Experimental Set-up - 14 - <br/>3.7.2 Water System - 15 - <br/>3.7.3 Electrical Systems - 15 - <br/>3.7.4 Market Research - 15 <br/>3.7.5 Measurements - 15 - <br/>3.7.6 Management & Co-ordination - 16 - <br/>4 Results & Analysis - 16 - <br/>Fully saturated pots without water flow at different air flow rates - 16 - <br/>4.1.1 Outlet air temperature (°C) & RH (%) with respect to inlet air temperature (°C) & RH (%): - 16 <br/>4.1.2 Temperature drop (°C) at different air flow rates - 18 - <br/>4.1.3 Wet-bulb efficiency (%) with respect to air flow rate (cfm) - 19 - <br/>Dry pots with water flow at different air flow rates - 20 - <br/>4.2.1 Outlet air temperature (°C) & RH (%) with respect to inlet air temperature (°C) & RH (%) - 20 - <br/>4.2.2 Temperature drop (°C) at different air flow rates - 20 - <br/>4.2.3 Wet-bulb efficiency (%) with respect to air flow rate (cfm) - 21 - <br/>4.2.4 Water consumption (L) - 22 - <br/>4.2.5 True power (W) consumption - 22 - <br/>4.2.6 Coefficient of Performance (COP) - 23 - <br/>Pots at different water flow rates - 23 - <br/>4.3.1 Temperature drop (°C) at different water flow rates - 24 - <br/>4.3.2 Wet-bulb efficiency (%) with respect to air flow rate (cfm) - 24 - <br/>Geometrical Variation - 25 - <br/>4.4.1 Outlet air temperature (°C) & RH (%) with respect to inlet air temperature (°C) & RH (%) - 25 - <br/>4.4.2 Temperature drop (°C) - 26 - <br/>4.4.3 Wet-bulb efficiency (%) with respect to air flow rate (cfm) - 26 - <br/>4.4.1 Water consumption (L) - 27 - <br/>4.4.2 True power (W) consumption - 27 - <br/>Advantages and Application of the System - 28 - <br/>Comparison with Different Evaporative Cooling Systems - 28 - <br/>5 Conclusion - 30 - <br/>References - 31 - <br/> |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Damle, Rashmin (Guide) |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | 2016 Batch |
891 ## - Topic | |
Topic | FT-PG |
891 ## - Topic | |
Topic | Masters of Technology in Building Energy Performance |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | Faculty of Technology | CEPT Library | CEPT Library | 08/09/2018 | Faculty of Technology | MBEP TH-0011 PRI | 019867 | 08/09/2018 | 08/09/2018 | Thesis |