Quantification of airflow patterns in a naturally ventilated building simulated in water table apparatus (Softcopy is also available) (Record no. 55065)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 02989nam a2200181Ia 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180908s9999||||xx |||||||||||||| ||und|| |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | MBEP TH-0008 |
Item number | MUN |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Mundhe, Pooja (PT500416) |
245 #0 - TITLE STATEMENT | |
Title | Quantification of airflow patterns in a naturally ventilated building simulated in water table apparatus (Softcopy is also available) |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | xvi,30,xxivp. |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | <br/>Table of Contents <br/>1. Introduction 1 <br/> 1.1 Background 1 <br/> 1.2 Significance of the study 2 <br/> 1.3 Problem statement 2 <br/> 1.4 Research Question 2 <br/> 1.5 Research Objectives 2 <br/> 1.6 Research Limitations 3 <br/> 1.7 Scope of the study 3 <br/> 1.8 Expected Outcomes 3 <br/>2. Literature Review 4 <br/> 2.1 Methods available for predicting natural ventilation performance 4 <br/> 2.2 Flow visualization 4 <br/> 2.3 Ventilation performance metrics 5 <br/> 2.3.1 Age of air 5 <br/> 2.3.2 Ventilation Efficiency 6 <br/> 2.3.3 Net Escape Velocity (NEV) 7 <br/> 2.3.4 Purging flow rate 7 <br/> 2.3.5 Air change Effectiveness 7 <br/> 2.3.6 Air Changes per Hour (ACH) 8 <br/> 2.4 Learning from the literature review 8 <br/>3. Research Methodology 9 <br/> 3.1Overview 9 <br/> 3.2 Natural Ventilation 10 <br/> 3.2.1 Simulating an Apartment in Water Table Apparatus 10 <br/> 3.2.2 Ventilation Metrics 10 <br/> 3.3 Photographic data to ventilation metrics 11 <br/> 3.3.1 Extracting pixel values 11 <br/> 3.3.2 Post processing the pixel values 12 <br/> 3.4 Concentration values to metrics 13 <br/> 3.5 Verification of quantification methodology 17 <br/>4. Results and Discussion 18 <br/> 4.1 Flow visualization of three single rooms with different window configuration 18 <br/> 4.1.1 Percentage of Dead Spots (% DS) 20 <br/> 4.1.2 Absolute Ventilation Efficiency (AVE) 21 <br/> 4.1.3 Air Changes per Hour (ACH) 21 <br/> 4.1.4 Dose 22 <br/> 4.1.5 Zone Mean Age of Air (ZMA) 23 <br/> 4.2 Flow visualization of a 3BHK apartment 23 <br/> 4.2.1 Percentage of Dead Spots (% DS) 24 <br/> 4.2.2 Absolute Ventilation Efficiency (AVE) 25 <br/> 4.2.3 Air Changes per Hour (ACH 26 <br/> 4.2.4 Dose 26 <br/> 4.2.5 Room Mean Age of Air (RMA) 27 <br/> 4.3 Comparative Analysis 28 <br/> 4.3.1 AVE vs % DS 28 <br/> 4.3.2 ACH vs RMA / % DS 28 <br/>5. Conclusion and Recommendation for future study 29 <br/>Conclusion 29 <br/>Recommendations for future study 30 <br/>6. References i <br/>7. Appendices iv <br/> |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Damle, Rashmin (Guide) |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | 2016 Batch |
891 ## - Topic | |
Topic | FT-PG |
891 ## - Topic | |
Topic | Masters of Technology in Building Energy Performance |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dewey Decimal Classification | Faculty of Technology | CEPT Library | CEPT Library | 08/09/2018 | Faculty of Technology | MBEP TH-0008 MUN | 019864 | 08/09/2018 | 08/09/2018 | Thesis |