Quantification of airflow patterns in a naturally ventilated building simulated in water table apparatus (Softcopy is also available) (Record no. 55065)

MARC details
000 -LEADER
fixed length control field 02989nam a2200181Ia 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180908s9999||||xx |||||||||||||| ||und||
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number MBEP TH-0008
Item number MUN
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Mundhe, Pooja (PT500416)
245 #0 - TITLE STATEMENT
Title Quantification of airflow patterns in a naturally ventilated building simulated in water table apparatus (Softcopy is also available)
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc 2018
300 ## - PHYSICAL DESCRIPTION
Extent xvi,30,xxivp.
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note <br/>Table of Contents <br/>1. Introduction 1 <br/> 1.1 Background 1 <br/> 1.2 Significance of the study 2 <br/> 1.3 Problem statement 2 <br/> 1.4 Research Question 2 <br/> 1.5 Research Objectives 2 <br/> 1.6 Research Limitations 3 <br/> 1.7 Scope of the study 3 <br/> 1.8 Expected Outcomes 3 <br/>2. Literature Review 4 <br/> 2.1 Methods available for predicting natural ventilation performance 4 <br/> 2.2 Flow visualization 4 <br/> 2.3 Ventilation performance metrics 5 <br/> 2.3.1 Age of air 5 <br/> 2.3.2 Ventilation Efficiency 6 <br/> 2.3.3 Net Escape Velocity (NEV) 7 <br/> 2.3.4 Purging flow rate 7 <br/> 2.3.5 Air change Effectiveness 7 <br/> 2.3.6 Air Changes per Hour (ACH) 8 <br/> 2.4 Learning from the literature review 8 <br/>3. Research Methodology 9 <br/> 3.1Overview 9 <br/> 3.2 Natural Ventilation 10 <br/> 3.2.1 Simulating an Apartment in Water Table Apparatus 10 <br/> 3.2.2 Ventilation Metrics 10 <br/> 3.3 Photographic data to ventilation metrics 11 <br/> 3.3.1 Extracting pixel values 11 <br/> 3.3.2 Post processing the pixel values 12 <br/> 3.4 Concentration values to metrics 13 <br/> 3.5 Verification of quantification methodology 17 <br/>4. Results and Discussion 18 <br/> 4.1 Flow visualization of three single rooms with different window configuration 18 <br/> 4.1.1 Percentage of Dead Spots (% DS) 20 <br/> 4.1.2 Absolute Ventilation Efficiency (AVE) 21 <br/> 4.1.3 Air Changes per Hour (ACH) 21 <br/> 4.1.4 Dose 22 <br/> 4.1.5 Zone Mean Age of Air (ZMA) 23 <br/> 4.2 Flow visualization of a 3BHK apartment 23 <br/> 4.2.1 Percentage of Dead Spots (% DS) 24 <br/> 4.2.2 Absolute Ventilation Efficiency (AVE) 25 <br/> 4.2.3 Air Changes per Hour (ACH 26 <br/> 4.2.4 Dose 26 <br/> 4.2.5 Room Mean Age of Air (RMA) 27 <br/> 4.3 Comparative Analysis 28 <br/> 4.3.1 AVE vs % DS 28 <br/> 4.3.2 ACH vs RMA / % DS 28 <br/>5. Conclusion and Recommendation for future study 29 <br/>Conclusion 29 <br/>Recommendations for future study 30 <br/>6. References i <br/>7. Appendices iv <br/>
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Damle, Rashmin (Guide)
890 ## - Country
Country India
891 ## - Topic
Topic 2016 Batch
891 ## - Topic
Topic FT-PG
891 ## - Topic
Topic Masters of Technology in Building Energy Performance
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Withdrawn status Home library Current library Date acquired Source of acquisition Full call number Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     Faculty of Technology   CEPT Library CEPT Library 08/09/2018 Faculty of Technology MBEP TH-0008 MUN 019864 08/09/2018 08/09/2018 Thesis
Excel To HTML using codebeautify.org Sheet Name :- Location Chart
Location Chart Basement 1 (B1) Class No. 600 - 649, 660 - 699
(B1) :Mezzanine 1 Class No. 700 - 728
(B1) :Mezzanine 2 Class No. 728.1 - 799, 650 - 659, Reference Books, Faculty work
Basement 2 (B2) Class No. 000 - 599, 800-999
Basement 3 (B3) (Please Inquire at the Counter for resources) Theses, Students' works, Bound Journals, Drawings, Atlas, Oversize Books, Rare Books, IS codes, Non-book Materials