Analysing the impact of thermal mass walls on indoor space temperature in hot and dry climate of Bhuj (Softcopy is also available ) (Record no. 54915)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03707nam a2200181Ia 4500 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180822s9999||||xx |||||||||||||| ||und|| |
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | MIAD TH-0144 |
Item number | KUL |
100 ## - MAIN ENTRY--PERSONAL NAME | |
Personal name | Kulkarni, Anupama (PD000516) |
245 #0 - TITLE STATEMENT | |
Title | Analysing the impact of thermal mass walls on indoor space temperature in hot and dry climate of Bhuj (Softcopy is also available ) |
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) | |
Date of publication, distribution, etc | 2018 |
300 ## - PHYSICAL DESCRIPTION | |
Extent | 117p. |
505 ## - FORMATTED CONTENTS NOTE | |
Formatted contents note | CONTENTS<br/>Abstract <br/>Acknowledgement <br/>List of figures 9 <br/>List of graphs 11 <br/>Chapter 1 <br/>Introduction 13 <br/>1.1 Purpose statement 15 <br/>1.2 Research question/s 15 <br/>1.3 Hypothesis 15 <br/>1.4 Research objectives 15 <br/>1.5 Scope and limitations of the study 16 <br/>1.6 Significance of the study 16 <br/>1.7 Research methodology 17 <br/>Chapter 2 <br/>Background 18 <br/>2.1 Thermal mass 19 <br/>2.1.1 Heat transfer 19 <br/>2.1.2 Why thermal mass 21 <br/>2.1.3 Important terms and formulas: Thermal time lag and Decrement factor 21 <br/>2.2 Materials and their properties 22 <br/>2.3 Criteria for the selection of materials for the study 23 <br/>2.3.1 Rammed earth 24 <br/>2.3.2 Adobe 25 <br/>2.3.3 Stone 26 <br/>2.3.4 CSEB blocks 26 <br/>2.4 Thermal comfort 28 <br/>2.5 Climate study 30<br/>Chapter 3 <br/>Literature review 34 <br/>3.1 Learnings from the literature 38 <br/>Chapter 4 <br/>Thermal performance of the case studies - onsite measurements 39 <br/>4.1 Data collection 42 <br/>4.1.1 Rammed earth wall 1 (W1) – description of the built space: 43 <br/>4.1.2 Adobe wall 2 (W2) – description of the built space: 50 <br/>4.1.3 Stone wall 3 (W3) – description of the built space: 56 <br/>4.1.4 CSEB blocks wall 4 (W4) – description of the built space: 62 <br/>4.2 Results and analysis 70 <br/>4.2.1 Comparing hear capacity and thermal conductivity 70 <br/>4.2.2 Effect of heat transfer with respect to wall thickness 71 <br/>4.2.3 Calculated Mean radiant temperature 72 <br/>Chapter 5 <br/>5.1 Space modelling details 76 <br/>5.1.1 Case 1 with 230 mm thick wall 73 <br/>5.1.2 Case 2 with 345 mm thick wall 74 <br/>5.1.3 Case 3 with 400 mm thick wall 75 <br/>5.2 Overall trend observed throughout the simulated readings 82 <br/>5.3 Rammed earth 83 <br/>5.3.1 Annual hourly temperature readings of rammed earth with 230 mm thick wall <br/>5.3.2 Annual hourly temperature readings of rammed earth with 345 mm thick wall <br/>5.3.3 Annual hourly temperature readings of rammed earth with 230 mm thick wall <br/>5.4 Adobe 87 <br/>5.4.1 Annual hourly temperature readings of adobe earth with 230 mm thick wall <br/>5.4.2 Annual hourly temperature readings of adobe earth with 345 mm thick wall <br/>5.4.3 Annual hourly temperature readings of adobe earth with 400 mm thick wall <br/>5.5 Stone 91 <br/>5.5.1 Annual hourly temperature readings of stone with 230 mm thick wall <br/>5.5.2 Annual hourly temperature readings of stone with 345 mm thick wall <br/>5.5.3 Annual hourly temperature readings of stone with 400 mm thick wall <br/>5.6 CSEB blocks 94 <br/>5.6.1 Annual hourly temperature readings of CSEB blocks with 230 mm thick wall <br/>5.6.2 Annual hourly temperature readings of CSEB blocks with 345 mm thick wall <br/>5.6.3 Annual hourly temperature readings of CSEB blocks with 400 mm thick wall <br/>5.7 Brick 97 <br/>5.7.1 Annual hourly temperature readings of brick with 230 mm thick wall <br/>5.7.2 Annual hourly temperature readings of brick with 345 mm thick wall <br/>5.7.3 Annual hourly temperature readings of brick with 400 mm thick wall <br/>Chapter 6 <br/>6.1 Conclusion 98 <br/>6.2 Future scope 99 <br/>References 102 <br/>Appendix 105 <br/><br/> |
700 ## - ADDED ENTRY--PERSONAL NAME | |
Personal name | Parekh, Deepa (Guide) |
890 ## - Country | |
Country | India |
891 ## - Topic | |
Topic | 2016 Batch |
891 ## - Topic | |
Topic | FD-PG |
891 ## - Topic | |
Topic | Masters in Interior Architecture and Design |
Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Withdrawn status | Home library | Current library | Date acquired | Source of acquisition | Full call number | Barcode | Date last seen | Price effective from | Koha item type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|